>>Download catalog
DIN7/16 series connectors for corrugated coaxial cables. Conform to the standards of DIN47223, IEC169-4 and CECC22190
Electrical |
Impedance |
50 Ohm |
Frequency Range |
7.5 GHz |
VSWR |
VSWR<1.10 (1-2 GHz)
VSWR<1.15 (2-3 GHz)
|
Operating Voltage |
Maximum 707 rms |
Dielectric Withstanding Voltage |
4,000 vdc |
Insulation Resistance |
10,000 M Ohm minimum |
Insertion Loss |
.05 frequency GHz |
Shielding Effectiveness |
Minimum 125 dB |
Peak Power |
Maximum 10 kW |
Average Power |
Maximum .60 kW |
3rd Order IM Product |
Typical -125 dBm (-168 dBc) |
Mechanical |
Mating |
MIL-STD-348 |
Inner Attachment Method |
Solder or captivated |
Outer Attachment Method |
Compression |
Assembly Torque |
18/22 lb-ft (25/30 N-m) |
Coupling Torque |
15.00 lb-in (1.70 N-m) |
Coupling Nut Retention Force |
100.00 lbs (444.80 N) |
Connector Durability |
500 cycles, 12 cycles/minute |
Material |
Body |
Brass, silver plated |
Outer Contacts |
Brass, silver plated |
Inner Contacts |
Beryllium copper, silver plated |
Other Metal Parts |
Brass, silver or trimetal plated |
Insulators |
PTFE |
Gaskets |
Silicone rubber |
Environmental |
Temperature Range |
Operating: -55 C to +155 C
Storage: -70 C to +100 C
|
Thermal Shock |
MIL-STD-202, method 107, test condition A-1 |
Immersion |
IEC 529, IP67 |
Vibration |
MIL-STD-202, method 204, test condition B |
Corrosion |
MIL-STD-202, method 101, test condition B |
Mechanical Shock |
MIL-STD-202, method 213, test condition I |
|